Gloves used for protection against chemotherapy drug exposure must be selected specifically for the type of chemicals used. Test results shown on reverse. Caution: Refer to drug labeling or MSDS sheet to determine adequate level of protection.
Physical Properties (Before Aging)*
Tensile Strength: 14 Mpa minimum
Elongation: 500% minimum
Length: 240mm minimum
Finger Thickness: 0.12mm minimum
Palm Thickness: 0.10mm minimum
*PremierPro™ gloves meet or exceed these physical requirements. Independent laboratory test results are available upon request.
Tested For Use With Chemotherapy Drugs Using ASTM D 6978. Gloves used for protection against chemotherapy drug exposure must be selected specifically for the type of drugs being used.
Chemical Permeation Data
Chemical permeation data of chemotherapy drugs and a Material Safety Data Sheet are available to the consumers upon request. For chemical resistance
data on chemotherapy drugs not listed, please call 1-855-531-7699.
Chemotherapy Drug Permeation Resistance
CHEMICAL TESTED | AVERAGE NORMALIZED BREAKTHROUGH TIME IN MINUTES |
Cisplatin, 1.0 mg/ml (1,000 ppm) | >240 |
Cyclophosphamide (Cytoxan), 20.0 mg/ml (20,000 ppm) | >240 |
Dacarbazine (DTIC), 10.0 mg/ml (10,000 ppm) | >240 |
Doxorubicin Hydrochloride, 2.0 mg/ml (2,000 ppm) | >240 |
Etoposide (Toposar), 20.0 mg/ml (20,000 ppm) | >240 |
5-fluorouracil, 50.0 mg/ml (50,000 ppm) | >240 |
Paclitaxel (Taxol), 6.0 mg/ml (6,000 ppm) | >240 |